Lixin Anti-fog Infrared Ray Automatic Sensing System
A.Working Principle
When someone comes in the sensing area, the sensor can detect the change of infrared spectrum of human body, then the sensor connects the loader and starts to work. When someone leaves the sensing area, it will stop after a while.
It’s very convenient, safe and energy-saving. It’s the top choice of hotel projects.
B. Sensors
1.Unipolar: unipolar power supply, two lines connection (connect with normal switch)
2.Bipolar: bipolar power supply, three lines connection(should add null line)
C. Technical parameters
1.Voltage : AC180-250V (50/60Hz)
2.Temperature :-20℃ to +50℃
3.Its own power :<0.016W
4.Load power: unipolar≤500W, bipolar≤1000W
5.Sensing angle: 140°
6.Sensing distance: 5-8M
7.Optical range: 5-500Lux±20%
8.Delay closing time: 16 - 180s±30%
9.Size: 86*86*35mm
D. Sketch map
E. Wiring diagram